[vc_row gap=”10″ woodmart_bg_position=”right-center”][vc_column css=”.vc_custom_1553779255930{border-width: 2px !important;padding: 55px !important;background-color: #f2f8fc !important;}”][vc_column_text]
USER MANUAL
FACIAL ANTI-AGING &
SLIMMING BODY MACHINE
[/vc_column_text][vc_row_inner][vc_column_inner css=”.vc_custom_1553779730362{border-width: 5px !important;padding: 55px !important;background-color: #ffffff !important;}”][vc_empty_space][vc_column_text]
HIFU Machine Instruction
[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner gap=”3″ css=”.vc_custom_1553780220393{background-color: #ffffff !important;}”][vc_column_inner width=”2/3″][vc_column_text]
An Overview of HIFU Machine
The latest high-end rejuvenating MONO beauty product with advanced ultrasonic scalpel appliances appears with three visible functions—FIRMING, RHYTIDECTOMY (face-lifting) and SHAPING. It adopts the most advanced ultrasonic power that able to penetrate and reach to the SMAS layer of the skin, improve the SMAS functions and comprehensively solve the facial skin aging and sagging problems with safer repairing mechanism. The ultrasonic scalpel skincare appliances have been recognized by beauty industry authority for no wound, no convalescence, no bleeding and multifarious treatment for face promotion. It is honored as magic light for forever young.
[/vc_column_text][vc_single_image image=”3875″ img_size=”medium” add_caption=”yes” alignment=”center” style=”vc_box_shadow_3d” onclick=”img_link_large”][/vc_column_inner][vc_column_inner width=”1/3″ css=”.vc_custom_1553741956658{margin: 3px !important;}”][vc_empty_space][vc_column_text]
CONTENTS OF THE PAGE
HIFU machine instruction
An overview of machine
Principle of machine
Technological superiority
Technical parameters
Operation of HIFU machine
Name of components
HIFU machine installation
Interface instruction
Operation steps
Curse of the treatment and reference for parameters setting
Notes for use and maintenance
Taboos for HIFU machine users
Handling and placement of HIFU machine
Troubleshooting
Maintenance of HIFU machine[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner][vc_single_image image=”3845″ img_size=”large” add_caption=”yes” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1553780682186{background-color: #ffffff !important;}”][vc_column width=”1/2″ css=”.vc_custom_1553780542869{background-color: #ffffff !important;}”][vc_column_text]
Principle of HIFU machine
High Intensity Focused Ultrasound (HIFU) machine has been rapidly evolving in these years for its non-invasive treatment. It has two predominant mechanisms, one of which is specific high-energy focused ultrasound and the other is accurate position of ultrasonic power into 4.5 mm. deep to SMAS layer. With its safer repairing mechanism, it performs the best effect of shaping, pulling and compacting of muscle growth and traction; and comprehensively solve the aging problems by recovering elasticity, skin whitening, wrinkle removing and pores shrinking.
[/vc_column_text][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1553780517030{background-color: #ffffff !important;}”][vc_column_text]
Technological Advantages
- MAX treatment area is comparatively wider in one shoot, so it shortens enough time to operate HIFU machine on one face or neck or body, as well as makes energy points of the skin be more uniform with better curative effect.
- It is equipped with three treating heads with most advanced high technology that can be applied accurately on various skin depths according to the facial skin condition.
- The power lightly crosses into the skin at agreed value by customers according to comfortability which ensure them to have a painless cure and there is no injury absolutely for its minimal power immersion mechanism.
- The heat effect reaches deep down to the facial skin and so the treatment effect is absolutely thermal.
- It is user friendly and no consumable items are required results greatly cost saving treatment.
[/vc_column_text][/vc_column][/vc_row][vc_row gap=”2″ css=”.vc_custom_1553781622192{border-width: 2px !important;padding: 55px !important;background-color: #f2f8fc !important;}”][vc_column css=”.vc_custom_1553781487635{background-color: #ffffff !important;}”][vc_column_text]
Technical Parameters
Operation voltage: 110V-240V Working frequency: 4MHz HIFU machine size:440mm*300mm*380mm MAX power:100VA Fuse:6A Net weight:10kgs |
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator style=”shadow” border_width=”3″][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text]
OPERATION OF HIFU MACHINE
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row gap=”3″][vc_column][vc_row_inner][vc_column_inner][vc_column_text][table id=1 /][/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text]
HIFU Machine Installation
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_single_image image=”3969″ img_size=”full” add_caption=”yes” alignment=”center” style=”vc_box_shadow_3d” onclick=”img_link_large”][vc_column_text][/vc_column_text][vc_row_inner][vc_column_inner][vc_separator border_width=”2″][vc_column_text]
DISPLAY INSTRUCTION
[/vc_column_text][vc_column_text][/vc_column_text][vc_empty_space][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Starting
Check whether the appliances are connected correctly. The dot line will appear after power on. The launch bar on the picture indicates that the device is starting and loading pressure.
Selection of Standby and Control Lever
The standby screen will appear like the picture during normal starting of the device. Corresponding treatment head will be selected depending on intensity. The red figure is the selected treatment head; moreover, it can be replaced for the need treating head by pulling out directly.
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”3850″ img_size=”full” add_caption=”yes” alignment=”center” onclick=”zoom”][/vc_column][/vc_row][vc_row][vc_column][vc_single_image image=”3885″ img_size=”large” add_caption=”yes” alignment=”center”][vc_separator style=”shadow” border_width=”4″][vc_column_text][table id=3 /][/vc_column_text][vc_separator style=”shadow” border_width=”4″][vc_row_inner][vc_column_inner width=”2/3″][vc_single_image image=”3889″ img_size=”medium” add_caption=”yes” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
Interface for Treating Face
Treat face by 4.5mm & 3.0mm depth cartridge separately。Interface for treating face selected:as our clinical test experiences ,we often adjust pitch 1.5mm and length 25mm and clearance 2.3mm(5lines)
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row gap=”3″][vc_column width=”1/4″][vc_column_text]
Interface for Treating Body
Treat body by 16.mm or 13mm or 10mm or 8mm or 6mm depth cartridge separately. Interface for treating body selected:as our clinical test experiences, we often adjust pitch1.5mm and length 25mm and clearance 1.1(10lines).
[/vc_column_text][/vc_column][vc_column width=”3/4″][vc_single_image image=”3959″ img_size=”medium” add_caption=”yes” alignment=”center”][vc_row_inner][vc_column_inner][vc_column_text]Remarks:Cartridge
(1) 4.5mm :neck:0.8J, the lower jaw:1.0J, jaw bones:0.7J ,cheeks:1.0J, temple:0.7 J, forehead:0.4J;
(2) 3.0mm: neck:1.0J, the lower jaw:1.0J, jaw bones:0.8J, cheeks:1.0J, temple:0.7J, forehead:0.6J;
(3) 1.5mm :neck 0.6J, temple(fishtail lines):0.5J, forehead:0.5J;
(4) 6.0mm:back:0.8J, accessory breast 0.6J, stomach:1.0 J;
(5) 8.0mm:accessory breast 0.7J , back:0.8 J, stomach:1.0 J;
(6) 10.0mm:back 0.8J , thigh:1.0J, stomach:1.2J;
(7) 13.0mm:stomach1.0 J, thigh:1.0J;
(8) 16.0mm:stomach0.8J, thigh:1.0J.
The above energy selected as our clinical test experiences(operator can adjust different energy according to patient’s demands)[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1553774422222{background-color: #f2f8fc !important;}”][vc_column][vc_column_text]
Operating Steps
- Please don’t shoot if the head is not positioned against skin or Acrylic (don’t empty shooting)
- Clean the applying area and dry up the face before using.
- Clean dirt properly from the parts needed before treatment.
- Replace the treating head needed before starting, and the power should be optimally ranged from low to high according to clients endurability.
- Keep the treating head flatten on the skin during operation and the distance between them should be impervious.
- Ask the client about the level of comfortability and adjust the power accordingly to keep the client comfortable during operation.
- Emphasize treatment on the problem areas.
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
Parameters Setting
Type of Skin | Width | Clearance | Power | Pitch | Length | Problem Skin | Severe Skin |
Good Skin | 0-10 |
1.0-5.0 |
0.25-0.5 |
1.0-2.0 | 0~10 | 1 times/course | 1 times/Month
3 times/Course |
Sensitive Skin | 0-10 | 1.0-5.0 | o.25-0.35 | 1.5-2.4 | 0~15 | 1 times/course |
[/vc_column_text][/vc_column][/vc_row][vc_row css=”.vc_custom_1553775406425{padding: 55px !important;background-color: #f2f8fc !important;}”][vc_column][vc_column_text]
Notes for Using and Maintenance
- Clean the appliances with water after every use.
- Use the plug with ground pins and make sure that the socket has been connected properly.
- Make sure the required voltage of machine. It is suggested to use voltage regulator with the machine if the local power voltage is unstable.
- Please use the accessories provided or suggested by the manufacturer for ensuring better result of the treatment and longevity of the machine.
- Do not place the machine in humid areas or close to the water source and in the area that exposed to sunlight.
- Never keep the machine near highly thermal sources because of the machine longevity and its normal application would be interrupted.
- Use the set of current loop arm in cold or dry air for avoiding defective uses. Pay attention to the areas that directly touch the skin and this area could be wet because of using water containing products or wiping with water.
- Any form of water and oil is prohibited in the machine, as well as scratching, thrashing and cracking may damage the device.
- Please clean the probe and disconnect from power after use.
[/vc_column_text][vc_separator color=”white” style=”shadow” border_width=”7″][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
Taboos For Machine Users
This machine must be used with enough caution in the following cases and advice from medical professionals are necessary prior the treatment. Some details are listed bellow:
- Clean physiotherapeutic part (outer or visible part) of the skin properly since the dirt on skin will prevent ultrasound penetrate deep into skin and remove all metallic objects from the area for avoiding unexpected situation which could wield to least curative effects.
- It is strongly recommended to use certain viscosity to facilitate better fusion between ultrasound and skin and prevent any reflection arising from gap from hampering acoustic and energy absorption.
- Generally each physical therapy will last upto 15 to 20 minutes, more time consuming and improper use of device will cause skin fatigue or worst result. The user may select appropriate duration considering the size of physiotherapeutic part.
- The degree of heat at the probe cannot be maintained equally as the ultrasonic power output; it is not advisable to penetrate low-concentration agent or drug directly, which will lead to dry skin.
- When this device is being used, the probe must be kept away from the eye and prohibited from passing through eyeball, during pregnancy and with patients have severe heart disease.
- Unless consultation with doctors, the patients having treatment should be restrained from using the machine.
- Patients with malignant tumor, hemophilia or severe bleeding; as well as any kind of diseases, like skin disease or infection will be treated cautiously enough in using this machine. And also with patients suffering from hyperthyroidism, asthma and hypertension.
- Enough caution must be given when the machine is used in the area of heart, brain, neck, nerve centre, spine, eyeball, bleeding and injection.
- Ultrasonic scalpel treatment is not allowed within 15 days after injection of hyaluronic acid.
- Restrict cleansing face with hot water and massage for one week; necessary to apply mask every day during the first week and please pay attention to be sun exposure, please don’t use any other beauty equipment (such as RF\Vacuum\ ultrasound\mechanical roller etc.) on treated skin before one month.
[/vc_column_text][vc_row_inner css=”.vc_custom_1553775439897{padding: 55px !important;background-color: #f2f8fc !important;}”][vc_column_inner width=”1/2″][vc_column_text]
Handling & Placement of HIFU Machine
1. The first layer of outer package- pearl wool
2. The second layer of outer package: carton with packing ribbon
3. Wooden box can be used for air or long-distance transportation
4. Removal of outer package of instrument
5. Removal of outer package of instrument
6. The wooden box can be opened from the top. But it is recommended to open it from the bottom and to draw it upwards.
Method to remove the carton
Step 1: Cut the rope with scissors
Step 2: Draw the carbon upward[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][vc_empty_space height=”60px”][vc_single_image image=”3946″ img_size=”full” add_caption=”yes” alignment=”center”][/vc_column_inner][/vc_row_inner][vc_separator color=”white” style=”shadow” border_width=”7″][/vc_column][/vc_row][vc_row gap=”2″ css=”.vc_custom_1553782340528{padding-top: 55px !important;padding-right: 55px !important;padding-bottom: 55px !important;padding-left: 55px !important;background-color: rgba(255,255,255,0.76) !important;*background-color: rgb(255,255,255) !important;}”][vc_column][vc_column_text]
Troubleshooting
- No display will be interfaced with machine: Please check if the power plug is inserted properly and the power switch is turned on.
- The machine operates normally but the press key malfunctions: Please check if the power supplier is connected properly.
[/vc_column_text][/vc_column][/vc_row][vc_row css=”.vc_custom_1553775532216{padding: 55px !important;background-color: #f2f8fc !important;}”][vc_column][vc_column_text]
Repairing & Maintenance Of The Machine
- Clean the appliances with water after every use.
- Use power plug with ground pins and make sure that the power outlet has been grounded properly.
- Make sure the required voltage of machine. It is suggested to use voltage regulator (stabilizer) with the machine if the local power voltage is unstable.
- Please use the accessories provided or suggested by the manufacturer for ensuring better result of the treatment and longevity of the machine.
- Do not place the machine in humid areas or close to the water source and in the area that is exposed to sunlight.
- Never keep the machine near highly thermal sources because of the machine longevity and its normal application would be interrupted.
- The machine should be avoided from extreme sources of heat, because it may affect the lifespan of the machine and its normal activities.
- Please remove all metallic objects from the area for avoiding unexpected situation which could wield to least curative effects.
- Ensure a certain degree of wetness at the part contacting with skin, which may be happened because of using water containing products or wiping with water.
- Please turn off the power when the machine remains idle and ensure that it is turned off before and after use for safety purposes.
- Please use this machine carefully and train its operators strictly with the instructions in users’ manual.
[/vc_column_text][vc_separator color=”white” style=”shadow” border_width=”7″][/vc_column][/vc_row]