[vc_row gap=”35″ content_placement=”bottom” css=”.vc_custom_1554378329735{border-top-width: 5px !important;border-right-width: 5px !important;border-bottom-width: 5px !important;border-left-width: 5px !important;padding-top: 55px !important;padding-right: 55px !important;padding-bottom: 55px !important;padding-left: 55px !important;background-image: url(http://areton-ltd.com/wp-content/uploads/2019/04/articlepic1-1.jpg?id=4203) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}”][vc_column][vc_column_text]

USER MANUAL
ALUMINIUM 2D HIFU MACHINE

[/vc_column_text][vc_row_inner][vc_column_inner][vc_empty_space][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_empty_space][vc_column_text]

CONTENTS OF THE MANUAL

HIFU machine instruction
An overview of machine
How HIFU works
What is SMAS layer
Principle of machine
Technological Advantages
Technical parameters
Operation of HIFU machine
Process of Taken Out the Cartridges
On-screen Functions of HIFU
Guidelines of HIFU Treatment on Face & Neck
Guidelines of HIFU Body Treatment
Cautions During HIFU Treatment
Notes for use and maintenance
Contraindications
Troubleshooting

[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”3999″ img_size=”full” alignment=”center”][/vc_column][/vc_row][vc_row el_id=”Overview”][vc_column][vc_empty_space height=”45px”][vc_column_text]

HIFU Machine Instruction

Overview of HIFU Machine

HIFU (High-Intensity Focused Ultrasound) is an advanced cosmetic technology which can significantly tighten and lift several areas of the face, reduce the signs of aging and improve the tone of the skin in a single session, with potentially long-lasting effects. There is no incisions or major injuries to the surface of the skin.

[/vc_column_text][vc_row_inner el_id=”hifu w”][vc_column_inner][vc_column_text]

How HIFU works?

HIFU is a non-invasive procedure that uses focused ultrasound energy. It targets deep dermis and SMAS; generates thermal coagulative zones in the targeted tissues without damaging epidermis and subcutaneous tissues. This focused energy causes a contraction of SMAS layer, as well as a denaturation and remodeling of the targeted collagen fibers resulting in NEOCOLLAGENESIS, which then produces significant skin tightening and lifting tissues.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner el_id=”smas”][vc_column_inner][vc_column_text css=”.vc_custom_1554189924106{background-color: #f6f7ed !important;border-radius: 2px !important;}”]

What is SMAS layer?

There are mainly three layers of our skin.

  • The epidermis is the outermost layer of skin:
  • The dermis, beneath the epidermis, contains tough connective tissue, hair follicles, and sweat glands.
  • The deeper subcutaneous layer is made of fat and connective tissue.

The SMAS-layer (Superficial Muscular Aponeurotic Layer) is located directly below the Subcutaneous Fat layer (Shown in the picture) of the skin. It consists of Collagen Fibers. The SMAS layer protects us from aging and sagging skin. When the level of SMAS weakens, human skin becomes saggy and looks elderly.

[/vc_column_text][vc_single_image image=”4012″ img_size=”large” add_caption=”yes” alignment=”center” onclick=”img_link_large”][vc_empty_space][vc_separator style=”shadow” border_width=”5″][/vc_column_inner][/vc_row_inner][vc_row_inner el_id=”prince”][vc_column_inner][vc_column_text]

Principles of HIFU Machine

  • The HIFU device penetrates focused ultrasonic energy into exact depth of skin.
  • The epidermal surface remains unaffected as long as the energy delivered is not excessive for the given focal depth.
  • Compared to other skin rejuvenation devices and technologies, HIFU produces good aesthetic outcomes while limiting unwanted side effects.
  • HIFU is absolutely non-invasive treatment.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner el_id=”technology”][vc_column_inner][vc_column_text]

Technological Advantages

  • HIFU is equipped with three different cartridges. These allow to have precise focusing and reduce damage of surrounding tissues, and also can reduce the consumable costs due to long lifespan of the cartridges.
  • Parameters saved in the memory setting allow easy and fast treatment. It is also possible to change the values in detail upon the user’s decision. Energy setting and spacing are easy to adjust and treatment time is fast.
  • It provides graphic user interface that maximizes the convenience for practitioners. Also, there is a foot switch which allows to reduce the practitioner’s tiredness.
  • More reasonable consumables cost of appliances allows to have relatively low treatment cost and so it also allows to offer retouch comfortably if there’s dissatisfaction.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner el_id=”para”][vc_column_inner][vc_column_text css=”.vc_custom_1554187874257{background-color: #ededed !important;}”]

Technical Parameters

Operation voltage: 110V-240V
Working frequency: 4MHz
HIFU machine size:440mm*300mm*380mm
MAX power:40VA
Fuse:6A                  net weight:15kgs

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_separator style=”shadow” border_width=”5″][vc_row_inner][vc_column_inner][vc_column_text][table id=1 /][/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row el_id=”operation”][vc_column][vc_row_inner el_id=”process”][vc_column_inner][vc_column_text]

Operation of HIFU Machine

Process Of Taken Out The Cartridge

[/vc_column_text][vc_single_image image=”4058″ img_size=”large” add_caption=”yes” alignment=”center”][vc_column_text css=”.vc_custom_1554170821333{background-color: #f7f7f7 !important;}”]

Instruction:

Image 1: The button of the cartridge is at 180°; rotate clockwise to 90°.
Image 2: Keep the button at 90° as shown in the picture.
Image 3: Pull out the cartridge directly as shown in the picture.
Image 4: There are three options of cartridge available — 1.5mm., 3.0mm. and 4.5mm

.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_separator style=”shadow” border_width=”5″][vc_row_inner][vc_column_inner][vc_column_text]

Aluminium 2D HIFU Machine

[/vc_column_text][vc_single_image image=”3845″ img_size=”large” add_caption=”yes” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner el_id=”function”][vc_column_inner][vc_column_text]

On-screen Functions of HIFU

[/vc_column_text][vc_single_image image=”4178″ img_size=”large” add_caption=”yes” alignment=”center”][vc_empty_space][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”3851″ img_size=”medium” add_caption=”yes” alignment=”center”][vc_empty_space][vc_column_text]

Selection of standby and control lever

When machine will start normally, the standby screen will look like the picture (Picture 2: Normal starting of HIFU machine). The treatment head will be selected based on type of problems of the skin.

[/vc_column_text][vc_single_image image=”3885″ img_size=”large” add_caption=”yes” alignment=”center” style=”vc_box_shadow”][vc_single_image image=”4179″ img_size=”full” add_caption=”yes” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_empty_space][vc_column_text]

Press START; the machine will start and look like the picture (Picture 1: Starting Interface). The dotted line indicates that the machine is starting and loading pressure.

On the interface, there are two modes—MODE PROFESSIONAL & TO GUIDE THE. They are similar.

1. WIDTH indicates the width of the energy area (Picture 3). The parameter of width starts from 0mm which means single line and the highest parameter of width is 10mm. The number of lines depends on the level of pitch. Pitch indicates the distance between lines. With increasing and decreasing the parameter of pitch, the number of lines will be decreased and increased respectively. At lowest level of pitch, the number of lines will be 11.

2. LENGTH indicates the length of energy area (Picture 3). The highest parameter of the length is 25mm.

3. CLEARANCE indicates the distance between points. The highest clearance is 5.0mm. The suggested level of clearance is 1.8-2.0mm.

4. PITCH indicates the distance between lines. The highest parameter of pitch is 5.0mm. The suggested level of pitch is 1.8-2.0mm (4-6 lines).

5. POWER indicates the intensity of energy. The points will become red; it means that the energy is being delivered (Picture 3) and also with increasing the power level, the size of the points will become larger. It is suggested to start the treatment at lower power setting and gradually increase according to customer’s acceptance.

6. PATIENT TOTAL displays total number of shot which has been delivered with particular cartridge.

7. M1, M2, M3, M4 and M5 are used to save data for future reference.

8. Both of the buttons on display in green means that the machine is connected properly.

9. DEPTH OF CARTRIDGE: There are eight types of cartridges and among     them, 1.5mm, 3.0mm and 4.5mm are used for face and neck.

  • 4.5mm used on neck and lower face.
  • 3mm used on neck, lower and upper face.
  • 1.5mm Used in thin, sagging skins (neck, upper and lower face)

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row][vc_row el_id=”guide”][vc_column][vc_column_text]

Guidelines for HIFU Treatment on Face & Neck

[/vc_column_text][vc_column_text]

The Aesthetic practitioner should use all  three cartridges; 1.5mm, 3.0mm and 4.5mm for treating face and neck and the treatment should be started using the deepest depth of cartridge, 4.5 mm, followed by 3.0 mm and finally by 1.5 mm to ensure High Intensity Ultrasound Energy is being delivered to all three depths of the skin. But in any case, it has to be in mind that each cartridge can only be used in certain areas of the face and neck, while others should be avoided. Once the cartridge is inserted into the handle, the screen will display the areas of the face where the treatment is permissible using respective cartridge.

[/vc_column_text][vc_single_image image=”4180″ img_size=”full” add_caption=”yes” alignment=”center”][vc_column_text]

The areas at the greatest risk for injury are throat and Marginal Mandibular Nerve, where the course of the nerve becomes relatively superficial. Therefore, it has to be treated with particular care. The prohibited areas are indicated in picture (Picture 4).

[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner el_id=”body”][vc_column_inner][vc_column_text]

HIFU Body Treatment

For treating body, the depth of cartridges are 6mm, 8mm, 10mm, 13mm and 16mm. Interface for treating body is selected upon clinical experiences.

[/vc_column_text][vc_single_image image=”4187″ img_size=”large” add_caption=”yes” alignment=”center”][vc_column_text]

Selection of cartridges
The depth of cartridges are selected upon clinical experiences. Practitioners can adjust different parameters according to patient’s acceptances.

1. Cartridge 6.0mm For back: 0.8J, accessory breast 0.6J, stomach:1.0 J
2. Cartridge 8.0mm For belly 1.0J, thigh:1.0J
3. Cartridge 10.0mm For back 0.8J , thigh:1.0J,  stomach:1.2J
4. Cartridge 13.0mm For stomach 1.0J, thigh:1.0J;
5. Cartridge 16.0mm For stomach .8J, thigh:1.0J;

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator style=”shadow” border_width=”5″][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row el_id=”operation”][vc_column width=”1/2″][vc_column_text]

Cautions During HIFU Treatment

  • Place treating head against skin and Keep it flatten during operation.
  • Clean the applying area and dry up the face before starting treatment.
  • Attach exact treating head before starting treatment, and start the treatment at lower power setting and gradually increase according to customer’s acceptance.
  • Emphasize treatment on the problem areas.

[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_empty_space height=”45px”][vc_single_image image=”4021″ img_size=”full” add_caption=”yes” alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_separator style=”shadow” border_width=”5″][/vc_column][/vc_row][vc_row el_id=”notes”][vc_column][vc_column_text]

Notes for Using and Maintenance

  • Use the plug with ground pins and make sure that the socket has been connected properly.
  • Please use the accessories provided or suggested by Areton Ltd. for ensuring better result of the treatment and longevity of the machine.
  • Do not place the machine in humid areas or close to water sources and in the area that exposed to sunlight.
  • Cartridges and handle need to keep clean and dry. Clean the cartridges using non-corrosive solvents; alcohol is useful for this purpose.
  • The cartridges are packaged in an anti-static package. In order to avoid breaking or damaging the cartridges, please keep the cartridges into packages for next use after wiping all other accessories using alcohol.
  • Poor Contact with the skin through the ultrasound conductive gel can cause the cartridges to deteriorate prematurely.
  • Switch off and unplug the the machine after its use.

[/vc_column_text][vc_separator style=”shadow” border_width=”5″][/vc_column][/vc_row][vc_row el_id=”contraindication”][vc_column][vc_column_text]

Contraindications

The few absolute contraindications include —

  • Active infection or open skin at the treatment site,
  • Cystic acne, and
  • Pregnancy.

Relative contraindications include medical conditions and medications that alter or impair wound healing. Such as —

  • Heart disease,
  • Diabetes,
  • Hyperthyroidism.

Another relative contraindication to HIFU treatment is the patient with unrealistic expectations of treatment.[/vc_column_text][vc_separator style=”shadow” border_width=”5″][/vc_column][/vc_row][vc_row el_id=”troubles”][vc_column][vc_column_text]

Troubleshooting

When the cartridge is not placed perpendicular to the face, the device could automatically power off; in this case restart the unit and place the cartridge perpendicular to the skin of the patient you are treating.